Varec Network Adapter 4000 Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Sítě Varec Network Adapter 4000. Varec Network Adapter 4000 Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 80
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Varec, Inc.
5834 Peachtree Corners East, Norcross (Atlanta), GA 30092 USA
Tel: +1 (770) 447-9202 Fax: +1 (770) 662-8939
www.varec.com
IOM003GVAE0809
4000 Tank Gauge Transmitter
Advanced Technology Transmitter for transmission of level and
temperature data from the tankside to inventory management
systems
Installation and
Operations Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 79 80

Shrnutí obsahu

Strany 1 - Operations Manual

Varec, Inc.5834 Peachtree Corners East, Norcross (Atlanta), GA 30092 USATel: +1 (770) 447-9202 Fax: +1 (770) 662-8939www.varec.comIOM003GVAE08094000

Strany 2

Tank Gauge Transmitterviii Installation and Operations Manual10.2 4000GEFMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 3 - Trademarks acknowledged

14000 Introduction1 Introduction1.1 Using This ManualThis manual is designed to assist the user with the installation, configuration, operation, maint

Strany 4 - Terms of Use

Introduction Tank Gauge Transmitter2 Installation and Operations Manual1.3 OperationThe ATT uses an incremental counting technique for determining li

Strany 5 - Safety Precautions

34000 Installation2 Installation2.1 OverviewThis section contains instructions for unpacking, mounting, grounding, and wiring the Varec Model 4000 Adv

Strany 6

Installation Tank Gauge Transmitter4 Installation and Operations Manual2.2 Mounting the EquipmentThe ATT is bolted to the Model 2500 Automatic Tank G

Strany 7

54000 Installation2.3 Grounding the EquipmentWarning! The ATT must be grounded before communication and power connections are made.An external groundi

Strany 8

Installation Tank Gauge Transmitter6 Installation and Operations ManualFigure 2-3: ATT Field Terminal Block Wiring2.4.4 Connecting Host Communication

Strany 9

74000 Installation2.4.5 ATT EIA485 WiringThe ATT uses a 2-wire EIA485 hardware interface to communicate with the Modbus master. EIA485 is a high spee

Strany 10 - Tank Gauge Transmitter

Installation Tank Gauge Transmitter8 Installation and Operations ManualFigure 2-5: Typical EIA485 System Wiring110/220 VAC 50/60 Hz.Model 8130 with o

Strany 11 - 1 Introduction

94000 Installation2.4.6 ATT Mark/Space WiringFor an ATT using the Mark/Space field communications option, the following additional wiring connections

Strany 13 - 2 Installation

Installation Tank Gauge Transmitter10 Installation and Operations Manual2.5 Connecting the RTDThe following list shows how the ATT is wired to an RTD

Strany 14 - 2.2 Mounting the Equipment

114000 Configuration3 ConfigurationThe Varec Model 4000 Advanced Technology Transmitter (ATT) must be configured for the specific tank, attached senso

Strany 15 - 2.4 Wiring

Configuration Tank Gauge Transmitter12 Installation and Operations ManualTable 3-1: Model 1200 Function KeysAlpha and numeric information is entered

Strany 16

134000 ConfigurationFigure 3-2: ATT Display Mode Menu Tree Figure 3-3: 1200 Hand Held Terminal3.3 Terminal Mode OperationThe 1200 Hand Held Terminal i

Strany 17 - 2.4.5 ATT EIA485 Wiring

Configuration Tank Gauge Transmitter14 Installation and Operations Manual3.4 Menu OperationFor example, when the Main Menu is displayed on the top li

Strany 18

154000 Configuration3.4.1 Main MenuMain Menu DescriptionQuick Setup2Initializes the ATT configuration parameters to a variety of preset configurations

Strany 19 - 2.4.6 ATT Mark/Space Wiring

Configuration Tank Gauge Transmitter16 Installation and Operations Manual3.4.2 Summary MenuSummary Menu DescriptionLevel Current level.Temperature Cu

Strany 20 - 2.5 Connecting the RTD

174000 Configuration3.4.3 Configuration MenuConfiguration Menu DescriptionLevel Units Level units used for display and Modbus data. FT-IN-16TH, M, or

Strany 21 - 3 Configuration

Configuration Tank Gauge Transmitter18 Installation and Operations Manual3.4.4 Host Menu3.4.5 Notes on Menu Items1 Only displayed if in Display Mode2

Strany 22

194000 Configuration4 Only displayed if host interface type is Mark/Space5 Only displayed if host interface type is Modbus6 Only displayed if host int

Strany 23 - 3.3 Terminal Mode Operation

i4000CopyrightAll rights reserved. Printed in the United States of America.Except as permitted under the United States Copyright Act of 1976, no part

Strany 24 - 3.4 Menu Operation

Configuration Tank Gauge Transmitter20 Installation and Operations Manual3.5.1 Imperial Fractional 1900 Quick Setup DefaultsGeneral ConfigurationLeve

Strany 25 - 3.4.1 Main Menu

214000 Configuration3.5.2 Imperial Decimal 1900 Quick Setup DefaultsGeneral ConfigurationLevel Units FT-IN-16thTemp Units FLevel Sensor ForwardDamping

Strany 26 - 3.4.2 Summary Menu

Configuration Tank Gauge Transmitter22 Installation and Operations Manual3.5.3 0-20 Meter 1900 Quick Setup DefaultsGeneral ConfigurationLevel Units M

Strany 27 - 3.4.3 Configuration Menu

234000 Configuration3.5.4 0-30 Meter 1900 Quick Setup DefaultsGeneral ConfigurationLevel Units MetersTemp Units CLevel Sensor ForwardDamping 0Temp Sen

Strany 28 - 3.4.5 Notes on Menu Items

Configuration Tank Gauge Transmitter24 Installation and Operations Manual3.5.5 Imperial Fractional 1800 Series Transmitter Quick SetupThe Imperial fr

Strany 29 - 3.5 Quick Setup

254000 Configuration3.5.9 Imperial Modbus Quick Setup DefaultsGeneral ConfigurationLevel Units FT-IN-16thTemp Units FLevel Sensor ForwardDamping 0Temp

Strany 30

Configuration Tank Gauge Transmitter26 Installation and Operations Manual3.5.10 Metric Modbus Quick Setup DefaultsGeneral ConfigurationLevel Units Me

Strany 31

274000 Maintenance and Troubleshooting4 Maintenance and Troubleshooting4.1 MaintenanceThe Varec Model 4000 Advanced Technology Transmitter (ATT) is de

Strany 32

Maintenance and Troubleshooting Tank Gauge Transmitter28 Installation and Operations Manual4.3 TroubleshootingThe ATT has provisions for hardware ala

Strany 33

294000 Maintenance and Troubleshooting4.4 ATT Status ConditionsThe ATT provides the following general status condition.4.5 ATT Configuration Error Che

Strany 34

Advanced Technology Transmitterii Installation and Operations ManualDisclaimer of WarrantiesThe contract between the Seller and the Buyer states the

Strany 35

Maintenance and Troubleshooting Tank Gauge Transmitter30 Installation and Operations Manual4.6 Model 1200 Error MessagesThe following error messages

Strany 36

314000 Specifications5 Specifications5.1 Specifications and Physical CharacteristicsThe following specifications apply to the Varec Model 4000 Advance

Strany 37 - 4.2 Battery Replacement

Specifications Tank Gauge Transmitter32 Installation and Operations Manual5.1.4 Level MeasurementItem DescriptionResolution 0.04 in (1.0 mm)Counter L

Strany 38 - 4.3 Troubleshooting

334000 Specifications5.2 Safety Agency Approvals5.2.1 Explosion ProofThe HART Level Encoder is ETL listed to the following standards for explosion pro

Strany 39 - 4.4 ATT Status Conditions

Specifications Tank Gauge Transmitter34 Installation and Operations Manual5.3 Major System Assemblies and ComponentsThe major assemblies and componen

Strany 40 - 4.6 Model 1200 Error Messages

354000 SpecificationsTable 5-1: Assembly/Component ListTable 5-2: Transmitter Adapter Kits ListNote! Items not listed here require factory servicing d

Strany 41 - 5 Specifications

Specifications Tank Gauge Transmitter36 Installation and Operations Manual

Strany 42 - 5.1.4 Level Measurement

374000 Ordering Information6 Ordering Information6.1 Order Codes10 CommunicationsGE GPE Loop CommunicationMX Mark Space Matrix (1600/1700)TI TIWAY Com

Strany 43 - 5.2 Safety Agency Approvals

Ordering Information Tank Gauge Transmitter38 Installation and Operations Manual

Strany 44

394000 Theory of Operation7 Theory of Operation7.1 OverviewThe Advanced Technology Transmitter (ATT) represents a flexible system for use in liquid le

Strany 45

iii4000Safety Precaution DefinitionsCaution! Damage to equipment may result if this precaution is disregarded.Warning! Direct injury to personnel or d

Strany 46

Theory of Operation Tank Gauge Transmitter40 Installation and Operations Manual7.3 Status Inputs and OutputsStatus inputs and outputs are accomplishe

Strany 47 - 6 Ordering Information

414000 Theory of Operation7.6.2 DampingThe ATT implements a damping scheme to stabilize the level and temperature in turbulent tanks. The amount of da

Strany 48

Theory of Operation Tank Gauge Transmitter42 Installation and Operations ManualThe supported Modbus functions and exceptions are indicated in the fol

Strany 49 - 7 Theory of Operation

434000 Theory of OperationWhen emulating an 1800 or 1900, battery low status can be reported as one of the dry-contact inputs or as an invalid level.N

Strany 50 - 7.6.1 Back-up Battery

Theory of Operation Tank Gauge Transmitter44 Installation and Operations Manual

Strany 51 - 7.9 Host Communication

454000 ATT Family of Products8 ATT Family of ProductsThe ATT product family consists of the 4000 ATT, the Model 4040 Display Unit, and the Model 4050

Strany 52 - Table 7-1: Modbus Functions

ATT Family of Products Tank Gauge Transmitter46 Installation and Operations Manual8.2 Model 4050 Digital Input/Output UnitThe Model 4050 is a digital

Strany 53 - 4000 Theory of Operation

474000 Modbus Implementation9 Modbus Implementation9.1 IntroductionThis protocol guide explains the operation of the Modbus protocol as described in t

Strany 54

Modbus Implementation Tank Gauge Transmitter48 Installation and Operations ManualTable 9-1: Modbus FunctionsNote! Exception: Because the ATT does not

Strany 55 - 8 ATT Family of Products

494000 Modbus Implementation9.4 Functions and Data FormatsThe Modbus data in the ATT is arranged in integer registers, floating point registers, and s

Strany 56 - 8.2.3 Relay Specifications

Advanced Technology Transmitteriv Installation and Operations Manual

Strany 57 - 9 Modbus Implementation

Modbus Implementation Tank Gauge Transmitter50 Installation and Operations ManualNote! In all of the following communication examples, the error chec

Strany 58 - Table 9-1: Modbus Functions

514000 Modbus Implementation9.5.2 Integer Data• Hexadecimal representation • 4124Decimal equivalent: 16,676The data returned for data address 56 is

Strany 59 - 9.5 Integer Registers

Modbus Implementation Tank Gauge Transmitter52 Installation and Operations Manual9.5.4 Coded DataCoded data represents a table look-up value. Data wr

Strany 60 - 9.5.1 Integer Data

534000 Modbus Implementation9.6 Floating-Point RegistersAlthough not part of the Modbus protocol specification, floating point numbers have been imple

Strany 61 - 9.5.3 Character Data

Modbus Implementation Tank Gauge Transmitter54 Installation and Operations Manual9.6.4 The One 32-bit Register FormatFunction code 65 (41 Hex) is use

Strany 62 - 9.5.5 Packed Bit Data

554000 Modbus Implementation9.7 Status BitsIn the ATT implementation, status bits contain alarms, commands, and status information. The state of a Mod

Strany 63 - 9.6 Floating-Point Registers

Modbus Implementation Tank Gauge Transmitter56 Installation and Operations Manual9.9 Data Out of RangeWhen integer data calculated by the ATT is outs

Strany 64 - 9.6.6 Floating Point Data

574000 Modbus ImplementationTermination resistors of 120 Ohms are shown at each end of the communication bus to minimize reflections on the line. Term

Strany 65 - 9.7 Status Bits

Modbus Implementation Tank Gauge Transmitter58 Installation and Operations Manual7 Bit Field CmdsBit Usage0 CANCEL ALT1 CLR LOCAL MODS2 RESTART3 SAVE

Strany 66 - 9.9 Data Out of Range

594000 Modbus Implementation28 Code Quick Setup Option0 - NONE 1 - ENG FRAC 18002 - ENG DEC 18003 - 0 TO 20 M 18004 - 0 TO 30M 18005 - ENG FRAC 19006

Strany 67 - 9.12 Integer Register Map

v40001 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1 Using This Manual . . . . .

Strany 68

Modbus Implementation Tank Gauge Transmitter60 Installation and Operations Manual210 Bit Field AlmStat211 Bit Field DiagStat212 Reserved Reserved213

Strany 69

614000 Modbus Implementation9.13 Floating Point Register Map9.14 Status Bit Register MapRegister Number Description012345678910 1112 1314 1516 1718 19

Strany 70

Modbus Implementation Tank Gauge Transmitter62 Installation and Operations Manual

Strany 71 - 9.14 Status Bit Register Map

634000 Optional Interfaces10 Optional InterfacesThe intent of the optional interfaces is to enable the ATT to co-exist along side older VAREC style an

Strany 72

Optional Interfaces Tank Gauge Transmitter64 Installation and Operations Manual10.5 4000WBFMOThis option can co-exist along side Whessoe Bus™ transmi

Strany 73 - 10 Optional Interfaces

654000GlossaryAdv Hi LevelAdvisory High Level alarm set point. When the product level exceeds this point an advisory alarm will be generated.Adv Hi Te

Strany 74 - 10.5 4000WBFMO

Tank Gauge Transmitter66 Installation and Operations ManualoCCelsius. A unit of measure for temperature readings. 0 oC is the freezing point for wate

Strany 75 - Glossary

674000Temp DbandTemperature Deadband. The band that a temperature alarm must clear before the alarm is reset.TempTemperature.TSUTank Polling Unit. A V

Strany 76

Tank Gauge Transmitter68 Installation and Operations Manual

Strany 77

694000NOTES

Strany 78

Tank Gauge Transmittervi Installation and Operations Manual3.5.5 Imperial Fractional 1800 Series Transmitter Quick Setup . . . . . . . . . . . . . 2

Strany 79

Your offical representativeVarec, Inc.5834 Peachtree Corners East, Norcross (Atlanta), GA 30092 USATel: +1 (770) 447-9202 Fax: +1 (770) 662-8939© 200

Strany 80 - Your official representative

vii40007.9 Host Communication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .417.10 Mark/Space Host Interface . .

Komentáře k této Příručce

Žádné komentáře